image/svg+xml Page-1 List.1 List.2 List.3 List.4 List.5 List.6 List.7 List.8 List.9 List.10 List.11
FM Transmitter Measurement Report
Created: 2019-10-24 16-51-05
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
102.00 MHz 5/5, 30 dBuV IMPULS
Pilot RDS Phase Difference
0.0 kHz 3.2 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 2,0 kHz
MIN Hold Max. Samples at Total Samples % above 77,0 kHz
14 kHz 39 kHz 6137 0,0000
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-1,3 dBr -0,66 dBr -0,3 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" IMPULS " 2203 0 (No PTY) 1 0 1 1 --:--
RT
"RADIO IMPULS - ZIJEME CESKOU MUZIKOU! "
AF EON
91.4, 92.1, 93.0, 94.0, 96.6, 98.4, 99.6, 102.7, 102.9, 104.3, 106.0 MHz -
FM Scope Max at: 39 kHz MIN: 14 kHz % above 77 kHz: 0,0000 Acquired: 2019/10/24 16:50:02 Total samples: 6137 Equivalent time: 0:05:06 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200 300
FM Scope MAX: -0,3 dBr MIN: -1,3 dBr AVE: -0,66 dBr % above 0,2 dBr: 0,0 Last value: -0,4 dBr (2019/10/24 16:50:01) 16:36 16:38 16:40 16:42 16:44 16:46 16:48 16:50 0 50 100 Dev. MAX [kHz] -2 -1 0 1 2 Pm [dBr] 0 5 Signal Quality