<LOGO>
FM Transmitter Measurement Report
Created: 2023-10-04 12-22-51
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
101.90 MHz 5/5, 39 dBuV R-PLUS
Pilot RDS Phase Difference
0.0 kHz 3.6 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 2,0 kHz
MIN Hold Max. Samples at Total Samples % above 77,0 kHz
6 kHz 42 kHz 18470 0,0217
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-1,2 dBr -0,75 dBr -0,3 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"R-PLUS " 2424 2 (Affairs) 1 0 0 0 12:22, 4.10.2023
RT
"Hlavni zpravy - rozhovory, komentare "
AF EON
91.3, 91.5, 92.6, 92.8, 93.3, 93.5, 93.9, 94.1, 95.4, 97.8, 100.8, 101.5, 101.9, 103.6, 107.2 MHz -
FM Scope Max at: 42 kHz MIN: 6 kHz % above 77 kHz: 0,0217 Acquired: 2023/10/04 12:22:48 Total samples: 18470 Equivalent time: 0:15:23 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400
FM Scope MAX: -0,3 dBr MIN: -1,2 dBr AVE: -0,75 dBr % above 0,2 dBr: 0,0 Last value: -0,9 dBr (2023/10/04 12:22:48) 12:08 12:10 12:12 12:14 12:16 12:18 12:20 12:22 -4 -2 0 2 4 Pm [dBr] 0 5 Signal Quality