image/svg+xml Page-1 List.1 List.2 List.3 List.4 List.5 List.6 List.7 List.8 List.9 List.10 List.11
FM Transmitter Measurement Report
Created: 2020-02-17 05-20-55
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
98.80 MHz 5/5, 34 dBuV FM4
Pilot RDS Phase Difference
6.8 kHz 2.1 kHz -84 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 2,0 kHz
MIN Hold Max. Samples at Total Samples % above 77,0 kHz
13 kHz 17 kHz 17455 0,0115
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-4,6 dBr -1,33 dBr 1,0 dBr 32,6
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" FM4 " A213 0 (No PTY) 0 1 1 1 5:20, 17.02.2020
RT
"Pippa - Dystop "
AF EON
98.8, 101.4, 102.1, 103.8, 104.0 MHz A203, A201, A602
FM Scope Max at: 17 kHz MIN: 13 kHz % above 77 kHz: 0,0115 Acquired: 2020/02/17 5:19:51 Total samples: 17455 Equivalent time: 0:14:32 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600 800
FM Scope MAX: 1,0 dBr MIN: -4,6 dBr AVE: -1,33 dBr % above 0,2 dBr: 32,6 Last value: 1,0 dBr (2020/02/17 5:19:50) 05:06 05:08 05:10 05:12 05:14 05:16 05:18 0 50 100 Dev. MAX [kHz] -4 -2 0 2 Pm [dBr] 0 5 Signal Quality