image/svg+xml Page-1 List.1 List.2 List.3 List.4 List.5 List.6 List.7 List.8 List.9 List.10 List.11
FM Transmitter Measurement Report
Created: 2020-05-24 18-40-54
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
95.40 MHz 5/5, 32 dBuV R-PLUS
Pilot RDS Phase Difference
0.0 kHz 4.0 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 2,0 kHz
MIN Hold Max. Samples at Total Samples % above 77,0 kHz
11 kHz 15 kHz 14046 0,0000
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-1,7 dBr -0,88 dBr 0,0 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"R-PLUS " 2424 1 (News) 1 0 0 0 18:41, 24.05.2020
RT
" R-PLUS R-PLUS R-PLUS R-PLUS "
AF EON
91.3, 92.6, 93.3, 93.5, 95.7, 97.9, 98.0, 98.2, 99.5, 101.9, 103.6 MHz -
FM Scope Max at: 15 kHz MIN: 11 kHz % above 77 kHz: 0,0000 Acquired: 2020/05/24 18:39:51 Total samples: 14046 Equivalent time: 0:11:42 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600
FM Scope MAX: 0,0 dBr MIN: -1,7 dBr AVE: -0,88 dBr % above 0,2 dBr: 0,0 Last value: -1,6 dBr (2020/05/24 18:39:51) 18:26 18:28 18:30 18:32 18:34 18:36 18:38 0 50 100 Dev. MAX [kHz] -2 -1 0 1 2 Pm [dBr] 0 5 Signal Quality