<LOGO>
FM Transmitter Measurement Report
Created: 2024-04-20 02-39-47
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
92.50 MHz 3/5, 26 dBuV JEDYNKA
Pilot RDS Phase Difference
7.4 kHz 37 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 2,0 kHz
MIN Hold Max. Samples at Total Samples % above 77,0 kHz
18 kHz 23 kHz 5261 0,0000
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-1,0 dBr 0,70 dBr 2,0 dBr 58,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"JEDYNKA " 3211 3 (Info) 1 0 0 1 2:39, 20.04.2024
RT
" olskie R "
AF EON
89.0, 91.2, 92.5, 92.8, 96.8, 98.8 MHz -
FM Scope Max at: 23 kHz MIN: 18 kHz % above 77 kHz: 0,0000 Acquired: 2024/04/20 2:39:44 Total samples: 5261 Equivalent time: 0:04:23 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 50 100 150