image/svg+xml Page-1 List.1 List.2 List.3 List.4 List.5 List.6 List.7 List.8 List.9 List.10 List.11
FM Transmitter Measurement Report
Created: 2020-02-17 03-00-16
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
89.40 MHz 5/5, 34 dBuV OE 3
Pilot RDS Phase Difference
6.8 kHz 2.2 kHz -84 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 2,0 kHz
MIN Hold Max. Samples at Total Samples % above 77,0 kHz
12 kHz 52 kHz 13824 0,0145
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-1,1 dBr 1,58 dBr 2,5 dBr 91,2
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" OE 3 " A203 1 (News) 1 0 1 1 3:00, 17.02.2020
RT
"OE3-Nachrichten, Wetter & Verkehr um Punkt am Punkt "
AF EON
88.0, 88.2, 88.4, 88.5, 88.8, 89.2, 89.4, 92.2, 97.4, 98.1, 98.3, 98.4, 98.7, 99.0, 99.2, 99.3, 99.4, 99.6, 99.8, 99.9, 101.4, 103.0 MHz A201, A602, A213
FM Scope Max at: 52 kHz MIN: 12 kHz % above 77 kHz: 0,0145 Acquired: 2020/02/17 2:59:13 Total samples: 13824 Equivalent time: 0:11:31 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200 300
FM Scope MAX: 2,5 dBr MIN: -1,1 dBr AVE: 1,58 dBr % above 0,2 dBr: 91,2 Last value: 2,1 dBr (2020/02/17 2:59:12) 02:46 02:48 02:50 02:52 02:54 02:56 02:58 0 50 100 Dev. MAX [kHz] -2 0 2 Pm [dBr] 0 5 Signal Quality