<LOGO>
FM Transmitter Measurement Report
Created: 2022-12-02 11-52-04
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
103.60 MHz 4/5, 57 dBuV COUNTRY
Pilot RDS Phase Difference
7.7 kHz 4.4 kHz 81 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 2,0 kHz
MIN Hold Max. Samples at Total Samples % above 77,0 kHz
11 kHz 35 kHz 19033 0,0315
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-1,9 dBr -0,73 dBr 0,0 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"COUNTRY " 2337 25 (Country) 1 0 1 1 --:--
RT
"MIKI RYVOLA and NEZMARI - ZEME TRI SLUNCI "
AF EON
87.7, 89.5, 90.3, 91.6, 91.8, 91.9, 92.2, 92.7, 95.5, 95.6, 96.4, 96.8, 96.9, 101.8, 103.6, 103.7 MHz -
FM Scope Max at: 35 kHz MIN: 11 kHz % above 77 kHz: 0,0315 Acquired: 2022/12/02 11:52:01 Total samples: 19033 Equivalent time: 0:15:51 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600
FM Scope MAX: 0,0 dBr MIN: -1,9 dBr AVE: -0,73 dBr % above 0,2 dBr: 0,0 Last value: -0,5 dBr (2022/12/02 11:52:01) 11:38 11:40 11:42 11:44 11:46 11:48 11:50 11:52 -4 -2 0 2 4 Pm [dBr] 0 5 Signal Quality