<LOGO>
FM Transmitter Measurement Report
Created: 2022-12-06 01-56-09
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
93.90 MHz 5/5, 74 dBuV
Pilot RDS Phase Difference
0.0 kHz 0.0 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 2,0 kHz
MIN Hold Max. Samples at Total Samples % above 77,0 kHz
0 kHz 22 kHz 19020 0,0000
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-7,2 dBr -5,51 dBr -4,3 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" " 0000 0 (No PTY) 0 0 0 0 --:--
RT
-
AF EON
-
FM Scope Max at: 22 kHz MIN: 0 kHz % above 77 kHz: 0,0000 Acquired: 2022/12/06 1:56:06 Total samples: 19020 Equivalent time: 0:15:51 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600 800
FM Scope MAX: -4,3 dBr MIN: -7,2 dBr AVE: -5,51 dBr % above 0,2 dBr: 0,0 Last value: -5,1 dBr (2022/12/06 1:56:06) 01:42 01:44 01:46 01:48 01:50 01:52 01:54 01:56 -5 0 Pm [dBr] 0 5 Signal Quality